We build rack power distribution units on German Type F outlets for European cabinets, from 4-outlet basic strips to metered, switched and ATS builds.
Whether you are a rack cabinet manufacturer, data center operator, IT equipment distributor, or system integrator, we can help evaluate your specifications and develop suitable Schuko PDU solutions.

A Schuko PDU takes one 16A 230V single-phase feed and divides it across 4 to 16 Type F outlets inside a 19-inch chassis. The feed enters through a CEE 7/7 plug, runs onto a one-piece copper busbar, and leaves through each outlet's own protective contact. Every outlet therefore shares that one 16A feed, so the outlet count sets convenience while the inlet breaker sets the limit.
The outlet is CEE 7/3, known as Type F, and it earths through two side clips rather than through a pin. The matching CEE 7/7 plug carries both the side clips and a socket-contact hole, so it seats in a German Type F outlet and in a French Type E outlet. Name the plug standard on the inlet cord, because a Type E-only cord will not earth reliably in a German rack.
| Parameter | Typical configuration |
| Socket standard | German Type F Schuko |
| Rated voltage | 230V AC |
| Rated current | 16A |
| Power supply | Single-phase AC |
| Frequency | 50Hz, subject to project requirements |
| Mounting | Horizontal 1U or 2U |
| Outlet quantity | Model-dependent |
| Housing | Aluminum or other specified material |
| Functions | Basic, metered, monitored, or switched |
Need a Schuko PDU for Your Rack Configuration?
Contact our team to discuss your electrical requirements, socket standards, and mounting specifications.
Different rack environments require different levels of power management.
Some installations only need reliable power distribution, while others require local electrical readings, remote monitoring, or individual outlet control.
Our Schuko PDU product range is organized around these functional requirements to help professional buyers identify suitable configurations.

A basic unit distributes the feed and displays nothing, so it suits stable loads behind a breaker you already trust. We build it from 4 to 16 Type F outlets in 1U and 2U, in aluminium housing with an optional two-pole switch behind a protective cover. It is the tier integrators stock for cabinets that never get remote attention, and it is the entry point of our basic pdu range.

A metered unit adds a V/A meter, so a technician standing at the open rack reads the load without a laptop. We fit either a basic V/A meter or a hot-swap meter that lifts out while the outlets stay energised. It answers the first capacity question without adding a network, and the metered pdu range carries it in 1U and 2U.

Per-outlet metering splits the total across branches, so a tenant can be billed or the one device drawing the extra amps can be found. We build it as 12 outlets in 2U, with the readings carried on the same RS-485 bus as the monitored tier. Choose it when the cabinet is shared and the cost has to be apportioned, which is the metered by outlet pdu case.

A monitored unit reports voltage, current, energy and breaker state to a head end while the outlets stay mechanically closed, which is the monitored pdu tier in one line. The Monitored 485 platform cascades up to 64 single-phase units on one RS-485 bus, with temperature, humidity and smoke sensors on the same loop. It suits sites that want the data but forbid remote switching, the usual split between facilities and IT.

A switched unit puts a relay behind each outlet, so a hung device is rebooted from the NOC instead of by a site visit. The controller exposes SNMP v1/v2c/v3, Modbus RTU and HTTPS, and reports per-outlet current, energy and power factor. Sequence the outlets on power-up and the inrush of a full cabinet stops tripping the upstream breaker, which is the argument for the switched pdu tier.
Tell us what you need to see, and what you need to switch.
Not sure whether you need a Basic, Metered, Monitored, or Switched Schuko PDU? Tell us about your equipment and power management requirements. We map that answer to one of the five tiers and send the matching model with its datasheet.
The mounting configuration of a Schuko PDU directly affects rack space utilization, equipment accessibility, and cable management.
For professional rack installations, horizontal and vertical mounting are two important configuration options.

A 1U unit takes 44.45 mm of rack height and carries 4 to 12 outlets, while a 2U unit doubles the row and reaches 16. The panel is 482.6 mm wide to the rack flange, which leaves a 450 mm opening for outlet mouldings and cable exits. Measure the depth behind the unit before you fix the U position, because a CEE 7/7 plug plus its cable bend needs more space than the chassis drawing shows on the 1u pdu sheet.

A vertical unit mounts on the cabinet’s rear post and takes no U position, which is the only way to add outlets to a rack that is already full. Our German vertical builds carry the outlet row on a 360-degree rotatable panel, so the sockets can be turned to face the door after the cabinet is dressed. Confirm post spacing and door clearance before ordering, because a 0u pdu shortens the usable depth at the rear.
Need a Specific Rack Mounting Configuration?
Send us your cabinet dimensions, available mounting space, and outlet requirements. Our team can help evaluate a suitable horizontal or vertical PDU design.
For equipment requiring improved power continuity, a conventional single-source PDU may not provide sufficient redundancy.
ATS, STS, and maintenance-bypass configurations address different power transfer and maintenance requirements.
Our Schuko PDU product planning includes several configurations for redundant power distribution applications.
An ATS unit takes two feeds and relays the load to the live one, with a mechanical transfer that interrupts the load briefly. We build it in 1U with 8 Type F outlets and two inlets, and the front panel shows which source is carrying. It fits single-corded equipment that tolerates a short break, which is why the ats pdu is specified with the ride-through time of the load.
An STS unit transfers with static switches instead of a relay, so the break is short enough for equipment that cannot ride through a relay transfer. We build the 8-outlet 1U version on the same chassis as the ATS, which keeps the two comparable on outlet layout and depth. Choose it where the load is critical and the budget allows the faster path, which is the sts pdu case rather than the ATS case.
A hot-swap unit adds a maintenance bypass, so the controller or a module can be lifted out while the outlets stay energised. Our 12-outlet 2U build carries the bypass on the front panel, and the bypass is mechanical rather than a software state. That is what makes a maintenance bypass pdu the right tier for a rack that cannot be scheduled down for a firmware change.
Planning a Redundant Power Distribution Project?
Share your dual-input power architecture, load requirements, and maintenance expectations. We can help evaluate a suitable Schuko ATS, STS, or hot-swap configuration.
Schuko rack PDUs are used in different equipment environments where reliable power distribution and suitable outlet compatibility are required.
The right configuration depends on the connected devices, installation space, power demand, and operational requirements.
In a colo the PDU is a billing instrument as much as a distributor, so per-outlet metering decides the model before outlet count does. We build the 12-outlet 2U metered-by-outlet unit for tenant racks, with readings on RS-485 into the operator’s DCIM. A/B feed pairs are supplied as two units with matching outlet layout, so a rack is dressed once and cabled twice, which is the colocation pdu pattern.


A network cabinet carries switches and routers on single cords, so a basic or metered unit covers it without a controller. We keep 8 outlets in 1U as the standard build for these cabinets, with the row spaced for angled plugs. Where the cabinet sits in an unmanned site, the switched tier takes over so a hung switch is rebooted remotely, which is the server rack pdu case.
AV racks draw low current but need outlets in the right places, because a processor, an amplifier and a media player never cluster together. We lay out 12 outlets across 2U to separate the always-on control gear from the power amplifiers on a switched group. A rotatable or OLED display helps here, since an AV cabinet is opened for service rather than watched, which is why we quote the av rack pdu with a display.


Outside the IT room the constraint becomes ingress, temperature and a hard-wired feed. We build these as fixed-cable units with a metal strain relief and a higher-temperature outlet module, and confirm the IP rating per project rather than per family. Where the PDU sits inside a machine, it is specified with the machine builder’s drawing, which is how an industrial pdu is quoted.
Need a Schuko PDU for Your Industry Application?
Tell us about your data center, server rack, AV installation, or equipment cabinet project. We can help identify a suitable PDU configuration.
We run production, moulding and testing in our own plant, which is why a drawing change is a schedule change and not a negotiation with a subcontractor.
We have built power distribution for more than 20 years, and rack PDU work has been the core since 2019. Engineering starts from the drawing: busbar current, outlet module, cord length and mounting are fixed before a sample is made. Six assembly lines plus our own injection moulding and laser cutting keep the housing, the module and the chassis in one plant.
An OEM order fixes what you specify and leaves the rest to us, while an ODM order starts from a product architecture we propose. We hold the drawing, the BOM and the packaging specification against a SKU, so the second order matches the first. Branding covers the housing print, the rating label and the carton.

Incoming copper, mouldings and cords are checked against the drawing before they reach a line. In process, the earth bond and the outlet wiring are checked at module stage, so a fault is caught before the chassis is closed. Every finished unit is aged, load-tested and its meter calibrated, and the record is filed against the serial.
We provide Schuko PDU solutions with compliance support for German and European markets, including CE, LVD, EMC, and RoHS documentation. Selected models are also available with GS or VDE certification to meet specific project requirements. Relevant certificates and compliance documents can be provided according to the selected product model.
Standard Schuko PDU configurations may not always meet the requirements of specialized rack systems or customer product lines.
OEM/ODM customization allows buyers to evaluate product specifications, mechanical structures, functional modules, and branding requirements according to their project needs.
Electrical changes are the ones that touch the certificate, so they are quoted together with the test they trigger. Outlet count and layout sit on the safe side, while voltage, current and inlet type sit on the reviewed side. Tell us the destination market with the specification, and the review answers both questions at once.
A new length is a new chassis drawing, not a cut-down standard part. We hold the extrusion, the end caps and the mounting ears in one plant, so a 1U to 0U change stays inside one tooling set. Send the cabinet drawing with the mounting points, and the chassis is drawn to it.
Monitoring is added as a module, so current metering, an LCD or OLED, RS-485 and relay control do not require redesigning the outlet row. The 485 monitor is hot-swappable, which means the function can be changed at the rack rather than at the factory. Protocols on the intelligent build include Modbus RTU, SNMP v1/v2c/v3 and HTTPS.
Private label covers the logo, the rating label, the manual and the carton, and each is a controlled file per SKU. The rating label is the one to get right, because it must match the certification file for that model and market. Send the artwork with the purchase order, and the label is proofed against the file before the run.

You send the rack spec, drawing or competitor part number.
→ We return a clarification list.

We check phase, load, input, outlets and protection.
→ 2D drawing and configuration sheet.

We build one or two units on the confirmed configuration.
→ Sample with test data, a few weeks.

You approve the sample; we run the route for your market.
→ Certificate and DoC.

Bulk build with first-article inspection.
→ 30–45 days, with the document pack.
Start Your Custom Schuko PDU Project
Have a drawing, existing PDU sample, or detailed product specification? Send it to our team for an engineering evaluation and quotation.
A typical YOSUN Schuko PDU is designed for 230V AC single-phase power with a rated current of 16A. At 230V and 16A, the theoretical maximum apparent power is 3,680VA. However, the actual usable capacity must also account for applicable electrical regulations, circuit protection, operating conditions, and equipment requirements. When selecting a PDU, consider the combined current consumption of all connected devices, potential startup currents, and future expansion needs. Our engineering team can help evaluate the appropriate electrical configuration for your project.
The number of Schuko outlets depends on the PDU’s size, mounting configuration, and electrical requirements. YOSUN offers Schuko PDUs with configurations ranging from 4 to 16 Type F outlets. For horizontal rack mounting, 1U models typically support 4–12 outlets, while 2U models can accommodate up to 16 outlets. Custom outlet configurations are also available to meet specific rack layouts and equipment requirements. All outlets share the same input power supply, so the total connected load must remain within the PDU’s rated current capacity.
Schuko PDUs commonly use a CEE 7/7 input plug, which is compatible with German Type F and French Type E socket systems. Depending on the project requirements, YOSUN can evaluate different input plug standards, power cable lengths, and cable configurations. Fixed-cable options are also available for industrial equipment cabinets and specialized installations. When requesting a quotation, customers should specify the destination country, input voltage, rated current, required plug standard, cable length, and whether a detachable or fixed power cable is preferred. This helps ensure proper grounding and electrical compatibility.
Yes. YOSUN provides OEM/ODM customization for Schuko PDU outlet quantity, spacing, orientation, and overall layout. This is particularly useful for server racks and AV cabinets where bulky power adapters or different equipment power cords may require additional clearance. Customers can provide a rack drawing, existing PDU sample, or detailed outlet layout requirements. Our engineering team can evaluate the mechanical design and prepare a 2D drawing for approval before sample production. Custom housing dimensions and mounting structures can also be developed for specialized applications.
Yes. Schuko PDUs can be connected to compatible UPS systems to distribute backup power to servers, networking equipment, and other critical devices. For standard applications, a Schuko PDU can distribute power from a UPS output to multiple connected devices. For installations requiring redundant power sources, YOSUN also offers Schuko ATS and STS PDU configurations. ATS models automatically transfer the connected load between two power inputs, while STS models use static switching technology for faster power transfer. When selecting a PDU for UPS integration, ensure that the voltage, current rating, input connector, output configuration, and total load are compatible with the UPS specifications.
Yes. Schuko PDUs are available with different levels of monitoring and control functionality to suit various power management requirements.
Basic PDU: Provides reliable power distribution without metering or remote monitoring.
Metered PDU: Displays local voltage and current readings, with optional hot-swappable metering modules.
Monitored PDU: Provides remote monitoring of voltage, current, energy consumption, and breaker status.
Switched PDU: Supports remote individual outlet control, allowing administrators to power-cycle connected equipment remotely.
Depending on the selected intelligent PDU configuration, communication options include RS-485, Modbus RTU, SNMP v1/v2c/v3, and HTTPS. Per-outlet monitoring is also available for applications requiring individual equipment energy tracking.
Before placing a bulk order, it is important to confirm that the selected Schuko PDUs meet your electrical, mechanical, functional, and compliance requirements. We recommend checking the following:
Electrical compatibility: Confirm the input voltage, current rating, frequency, plug standard, and total connected load.
Outlet configuration: Verify the number, spacing, and orientation of outlets against your equipment requirements.
Rack compatibility: Check the mounting type, rack dimensions, available installation space, and cable clearance.
Functional requirements: Determine whether basic distribution, metering, remote monitoring, or individual outlet switching is required.
Safety and certification: Confirm the applicable CE, LVD, EMC, RoHS, and any project-specific GS or VDE documentation.
Sample approval: Request samples to verify product construction, outlet layout, cable configuration, and electrical performance before mass production.
Production and delivery: Confirm the order quantity, lead time, packaging specifications, quality inspection requirements, and documentation.
Working with an experienced PDU manufacturer can help reduce compatibility issues and ensure consistent product quality across large-scale deployments. YOSUN supports OEM/ODM development, sample testing, bulk production, and project-specific customization.

A Professional And Leading Manufacturer
For OEM
& ODM Power Distribution Unit (PDU)
You Can Trust
CONTACT
Ningbo YOSUN Electric Technology Co., LTD
Leading Professional Manufacturer in PDU Power Solutions
Contact Info.
Leave Your Message