WordPress Themes

T/H sensor

In order to ensure stability, this product, which is a photoelectric smoke and temperature integrated detector (henceforth referred to as the detector), has a unique structure design and uses MCU intelligent processing of optical signal. It also has anti-light interference, dust-proof, insect-resistant, and other features. This product reacts well to visible smoke from open combustion or slow smoldering. This product has a temperature sensor and a photoelectric smoke sensor. The detector will sound an alarm when the ambient temperature rises above 57°C or the ambient smoke concentration reaches the alarm level. The device can be used to detect smoke in a variety of settings, including homes, factories, hotels, offices, classrooms, banks, libraries, and warehouses.

Categories:

Features

  1. MCU automatic processing technology is adopted to improve product stability
  2. Temperature sensor + smoke sensor
  3. Fault self-test function
  4. Low voltage prompt
  5. Automatic reset
  6. Infrared photoelectric sensor
  7. Sound and light alarm /LED indicator alarm
  8. SMT process manufacturing, strong stability
  9. Dust-proof, insect-proof, anti-white light interference design
  10. Relay switching signal output (normally open, normally closed optional)

Details

  1. Working power supply:
  2. Static current: < 10uA 12-24VDC DC (Networking type)
  3. Alarm temperature: 54℃~65℃
  4. Alarm pressure: ≥85dB/3m
  5. Operating temperature: -10℃ ~ +50℃
  6. Relative temperature: ≤90%RH
  7. Dimension: φ126 *36mm
  8. Installation height: no more than 3.5 meters above the ground (installation height beyond,
  9. Professional and technical personnel are required to install the smoke collecting bin equipment, the height limit is not more than 4 meters)
  10. Detection area: no more than 20 square meters (according to the actual area increase
  11. Increase the number of detectors accordingly)
  12. Alarm current: < 80mA

Notes

The following variables may have an impact on the products’ measured values:
  1. Error in temperature
    • In the test environment, the stability time is too short.
    • In the sun, near a heat source, or near a cold source.
  2. Error in humidity.
    • In the test environment, the stability time is too short.
    • Avoid prolonged exposure to steam, water mist, water curtains, or condensation.
  3. Unclean ice
    • The product needs to be cleaned frequently in dusty or other contaminated environments.