How to Monitor Power Usage in Data Centers

Table of Contents
How to Monitor Power Usage in Data Centers

Monitoring power usage in power datacenters is critical for maintaining efficiency and reducing costs. These facilities consume over 2% of electricity in the United States, with average Power Usage Effectiveness (PUE) values reaching 1.6 in 2020. Targeting a PUE below 1.5 can save billions of dollars nationwide. By optimizing energy consumption, you can lower operational expenses and improve performance.

Flexential’s advanced systems, including dynamic load management and IoT sensors, show how cutting-edge technologies optimize energy use in power datacenters while supporting sustainability goals. Tools like AI and machine learning further reduce waste by adjusting environmental controls to workload patterns.

Why Monitor Power Usage in Power Datacenters?

Reducing Operational Costs

Monitoring power usage in power datacenters helps you identify inefficiencies that drive up operational costs. By tracking metrics like Power Usage Effectiveness (PUE), you can pinpoint areas where energy is wasted and implement strategies to reduce consumption. For example:

  • Lower PUE values indicate better energy efficiency, which translates into cost savings.
  • Tracking PUE over time allows you to measure the impact of energy-saving measures and refine your approach.

When you optimize power distribution, you minimize unnecessary energy expenses. This approach not only reduces costs but also ensures that your data center operates at peak efficiency. Proper power management also prevents equipment overloads, which can lead to costly repairs or downtime.

Enhancing Energy Efficiency

Energy efficiency is a cornerstone of modern data center operations. By monitoring power usage, you can adopt strategies like server virtualization, which reduces the number of physical servers required. This method alone can save between 10% and 40% of energy by improving server utilization and lowering cooling demands.

Energy efficiency metrics have evolved significantly over the past two decades. These metrics help you evaluate conservation efforts and eco-friendly designs in your power datacenter. For example:

  1. Metrics like PUE provide insights into how effectively energy is used.
  2. They highlight areas where improvements can lead to significant energy savings.
  3. Comprehensive metrics enable better evaluation of energy-saving measures.

By focusing on energy efficiency, you reduce waste heat and cooling energy demands, ensuring your data center operates sustainably while maintaining optimal performance.

Supporting Sustainability Goals

Power datacenters consume over 2% of global energy, a figure comparable to the aviation industry. Without sustainability measures, this number could rise to 8% by 2030. Monitoring power usage allows you to track greenhouse gas emissions and implement energy-saving measures that reduce your carbon footprint.

Modern technologies, such as smart PDUs, enable real-time monitoring of energy outputs. These tools help you optimize energy efficiency and produce more with less energy. Additionally, monitoring rack-level environmental data ensures servers operate within safe temperature ranges. Overheating servers consume more power, so real-time data helps you prevent energy waste and maintain sustainability.

By adopting energy-saving measures and leveraging advanced tools, you align your data center operations with global sustainability goals. This approach not only benefits the environment but also enhances your facility’s reputation as a responsible and forward-thinking organization.

Preventing Downtime and Overloads

Downtime in a data center can disrupt operations, cause financial losses, and damage your reputation. Overloads, on the other hand, can lead to equipment failure and safety hazards. Monitoring power usage helps you prevent these issues by providing real-time insights into your data center’s energy consumption and capacity.

Identify Overloaded Circuits Early

Power monitoring tools allow you to track energy usage at the circuit level. This data helps you identify circuits that are nearing their maximum capacity. For example, if a circuit consistently operates at 90% of its limit, it risks overheating or tripping. By addressing this early, you can redistribute the load or upgrade the circuit to handle more power.

Tip: Use intelligent PDUs like NBYOSUN‘s 42U IEC 36 C13 6 C19 3Phase Monitored IP PDU to monitor circuit-level energy consumption. These devices provide real-time alerts when circuits approach their thresholds, helping you take action before problems arise.

Balance Power Distribution Across Racks

Uneven power distribution can strain certain racks while leaving others underutilized. Monitoring tools help you visualize energy usage across all racks in your data center. This insight enables you to balance the load effectively, ensuring no single rack becomes a bottleneck. Balanced power distribution also improves cooling efficiency, as evenly distributed loads generate less concentrated heat.

Prevent Equipment Overheating

Overheating is a common cause of downtime in data centers. Servers and other equipment generate heat as they operate, and excessive heat can lead to malfunctions or permanent damage. Monitoring power usage often includes tracking environmental factors like temperature and humidity. For instance, NBYOSUN’s smart PDUs come equipped with sensors that monitor ambient conditions. These sensors alert you when temperatures exceed safe limits, allowing you to adjust cooling systems or redistribute workloads.

Set Alerts for Critical Thresholds

Modern power monitoring systems let you set alerts for critical thresholds. For example, you can configure alerts for high energy consumption, abnormal temperature spikes, or overloaded circuits. These alerts notify you immediately, enabling you to respond quickly and prevent downtime. Proactive monitoring reduces the risk of unexpected failures and ensures your data center remains operational.

Real-Life Example: Avoiding Downtime with Smart Monitoring

A global telecommunications company once faced frequent outages due to overloaded circuits in its data center. After implementing NBYOSUN’s smart PDUs, the company gained real-time visibility into its power usage. The PDUs provided alerts when circuits approached their limits, allowing the IT team to redistribute loads and avoid outages. This proactive approach saved the company thousands of dollars in repair costs and improved its service reliability.

Note: Downtime costs can range from $5,600 to $9,000 per minute, depending on the size and scope of your operations. Investing in advanced monitoring tools can save you significant expenses in the long run.

Optimize Maintenance Schedules

Monitoring power usage also helps you plan maintenance more effectively. By analyzing energy consumption trends, you can identify equipment that operates inefficiently or shows signs of wear. For example, a sudden spike in power usage might indicate a failing component. Addressing these issues during scheduled maintenance prevents unexpected breakdowns and minimizes disruptions.

Conclusion

Preventing downtime and overloads requires a proactive approach to power management. By leveraging advanced tools like NBYOSUN’s smart PDUs, you gain the insights needed to maintain operational stability. Monitoring power usage not only protects your equipment but also ensures your data center runs efficiently and reliably.

Key Metrics for Data Center Power Usage

Power Usage Effectiveness (PUE)

Power Usage Effectiveness (PUE) is one of the most important metrics for evaluating energy efficiency in data centers. It measures how effectively a facility uses energy by comparing the total energy consumption to the energy used by IT equipment. A lower PUE value indicates better efficiency, with the ideal target being 1.0.

For example, the average PUE across data centers is reported to be 1.58, suggesting room for improvement in many facilities. By monitoring PUE, you can identify inefficiencies in cooling systems, lighting, and other non-IT energy uses. This metric also helps you track the impact of energy-saving measures over time.

MetricDescription
Power Usage Effectiveness (PUE)A measure of how efficiently a data center uses energy; lower values indicate better efficiency.
Carbon Usage Effectiveness (CUE)Evaluates the carbon footprint by comparing emissions to energy consumed by IT equipment.
Water Usage Effectiveness (WUE)Tracks water efficiency by comparing consumption to energy used by IT equipment.

Tip: Regularly monitor PUE to ensure your data center operates at optimal energy efficiency levels.

Inlet and Outlet Power Consumption

Monitoring inlet and outlet power consumption provides valuable insights into energy consumption levels across your data center. Inlet power refers to the energy entering the facility, while outlet power measures the energy consumed by IT equipment. Comparing these values helps you identify energy losses and optimize power distribution.

Studies show that inlet air temperature significantly influences server power consumption. For instance, experimental setups have demonstrated that adjusting inlet temperatures can improve model accuracy by up to 13.6%. This highlights the importance of monitoring environmental factors alongside power metrics.

Study/ModelKey FindingsMeasurement Method
Wang et al. [13]Investigated impact of inlet air temperature on server power; improved model accuracy by 1%, 5.2%, and 13.6% at different temperatures.Experimental setup
Ham et al. [27] & Garraghan et al. [28]Used die temperature for modeling; average standard error of 3% in power usage.Experimental validation

Note: Use intelligent tools like NBYOSUN’s smart PDUs to monitor inlet and outlet power consumption accurately.

Cooling Efficiency Metrics

Cooling efficiency plays a critical role in maintaining energy efficiency in data centers. Cooling systems often account for a significant portion of energy consumption, making it essential to monitor their performance. Metrics like cooling efficiency help you evaluate how effectively cooling systems manage heat generated by servers.

For example, midsize data centers are known to be more energy-efficient but tend to consume more water due to cooling systems. Tracking cooling efficiency metrics allows you to balance energy and water usage effectively.

To improve cooling efficiency, consider strategies like optimizing airflow, using advanced cooling technologies, and monitoring ambient conditions. NBYOSUN’s smart PDUs include sensors for temperature and humidity, enabling real-time adjustments to cooling systems.

Tip: Regularly analyze cooling efficiency metrics to reduce energy waste and maintain optimal server performance.

Rack Power Density

Rack power density measures the amount of energy consumed by equipment within a single rack. Managing this metric is essential for optimizing energy usage and ensuring the reliability of your data center. As technology advances, the power density of racks continues to rise, creating new challenges for energy management.

Racks vary in density based on their energy consumption:

  • Standard density racks consume up to 10kW.
  • High-density racks range from 10kW to 30kW.
  • Ultra high-density racks consume between 30kW and 85kW.

This variation highlights the importance of monitoring rack power density to accommodate increasing demands. For example, training one machine learning model can consume as much energy as 100 homes, while Bitcoin mining uses more power annually than Argentina. These examples demonstrate the growing energy needs of modern data centers.

YearAverage Power Density (kW/rack)Percentage of Data Centers Reporting High Density
20104-5N/A
20208-10N/A
202220-2910%
202230-397%
202250+5%

As the table shows, average rack power density has increased significantly over the years. In 2010, racks consumed 4-5kW on average, but by 2022, some racks exceeded 50kW. This trend underscores the need for effective power density management to prevent overheating and ensure efficient cooling.

Tip: Use smart PDUs like NBYOSUN’s 42U IEC 36 C13 6 C19 3Phase Monitored IP PDU to monitor rack-level power density. These devices provide real-time data and alerts, helping you optimize energy distribution and avoid overloads.

Energy Usage Trends Over Time

Energy usage in data centers has evolved dramatically over the past decade. Between 2010 and 2018, global IP traffic increased tenfold, while data center storage capacity grew 25 times. Compute instances also rose sixfold during this period. Despite these increases, global data center energy consumption only grew by 6%, thanks to advancements in energy-efficient technologies.

Time PeriodGlobal IP Traffic IncreaseData Center Storage Capacity IncreaseTotal Compute Instances IncreaseGlobal Data Center Energy Consumption Change
2010-201810 times25 times6 times6% increase

These trends highlight the importance of monitoring energy usage over time. By tracking metrics like PUE and rack power density, you can identify inefficiencies and implement strategies to reduce energy waste. For example, adopting server virtualization and optimizing cooling systems can significantly lower energy consumption.

Note: Monitoring energy usage trends helps you adapt to changing demands and maintain sustainable operations. Tools like NBYOSUN’s smart PDUs provide real-time insights, enabling you to make informed decisions and improve efficiency.

Tools and Technologies for Data Center Energy Management

Intelligent Power Distribution Units (PDUs) like NBYOSUN’s 42U IEC 36 C13 6 C19 3Phase Monitored IP PDU

Intelligent Power Distribution Units (PDUs) are essential for optimizing data center power infrastructure. These devices provide real-time monitoring and control over energy consumption, helping you improve energy efficiency and reduce operational costs. NBYOSUN’s 42U IEC 36 C13 6 C19 3Phase Monitored IP PDU stands out as a powerful solution for managing power distribution in data centers.

This PDU integrates a GE smart IP meter, enabling precise tracking of energy usage and environmental conditions. You can monitor power consumption remotely through LAN, WAN, or the Internet, ensuring flexibility and control. The device also includes features like smoke detection, temperature monitoring, and overload alarms, which enhance safety and reliability.

The impact of using intelligent PDUs like NBYOSUN’s is significant:

MetricValue
Annual savings$50,000
Decrease in downtime incidents30%
Expected market growth (2025-2030)8.01% CAGR
Global PDU market size (2025)$2.78 billion
Global PDU market size (2030)$4.08 billion

These metrics highlight the financial and operational benefits of adopting intelligent PDUs. By leveraging this technology, you can enhance your data center energy management and ensure sustainable operations.


Data Center Infrastructure Management (DCIM) Software

DCIM software is a cornerstone of modern data center energy management. It provides a centralized platform for monitoring and optimizing energy usage across your facility. With DCIM, you can track key metrics like Power Usage Effectiveness (PUE) in real-time, enabling you to identify inefficiencies and implement corrective measures.

This software offers several practical benefits:

  • It generates ghost server reports, helping you deactivate underutilized servers and conserve energy.
  • It collects live data from power meters and environmental sensors, offering actionable insights for achieving carbon neutrality.
  • It facilitates the integration of advanced cooling systems and virtualization, boosting energy efficiency.

DCIM software also supports upgrading to energy-efficient IT equipment, ensuring your data center remains competitive and sustainable. By adopting this tool, you gain the ability to manage energy consumption effectively while reducing costs and environmental impact.


Environmental Sensors for Temperature and Humidity

Maintaining optimal temperature and humidity levels is critical for the performance and longevity of your data center equipment. Environmental sensors play a vital role in achieving this balance. These devices monitor ambient conditions and provide real-time data, allowing you to adjust cooling systems and prevent overcooling or overheating.

One of Vaisala’s customers estimated that a mere 1°C in overcooling could increase annual cooling energy costs by up to 8.5 percent. For a small data center, this could lead to increased energy costs of over 0.4 million Euros over 10 years, and for a large data center, it could cost over 4 million Euros.

By using environmental sensors, you can avoid unnecessary energy expenses and ensure your data center operates efficiently. NBYOSUN’s smart PDUs include built-in sensors for temperature and humidity, providing a comprehensive solution for monitoring environmental conditions. These sensors help you maintain energy-efficient operations while protecting your equipment from damage caused by extreme conditions.

Smart Meters and Energy Monitoring Systems

Smart meters and energy monitoring systems play a vital role in managing power usage in data centers. These tools provide real-time insights into energy consumption, helping you optimize operations and reduce costs. By using these systems, you gain the ability to track energy usage at a granular level, identify inefficiencies, and implement corrective measures.

Why Smart Meters Matter

Smart meters offer detailed tracking of energy consumption. They help you understand how much power each device or rack uses, allowing you to pinpoint areas of waste. This data enables efficient energy management, ensuring your data center operates at peak performance.

Tip: Use smart meters to monitor energy usage trends over time. This helps you identify abnormal consumption patterns and adjust operations accordingly.

Benefits of Energy Monitoring Systems

Energy monitoring systems simplify the process of managing power usage. They provide intuitive dashboards and visualization tools, making it easy to analyze data and make informed decisions. These systems also connect various devices, enabling centralized monitoring and control.

Here are some key benefits:

  • Efficient energy management reduces unnecessary costs.
  • Real-time monitoring promotes sustainable energy practices.
  • Intuitive dashboards save time by simplifying data analysis.

How These Tools Save Time and Costs

Smart meters and energy monitoring systems streamline energy management. They identify abnormal consumption patterns, saving up to 90% of analysis time. This efficiency translates into significant cost savings, as you can address issues before they escalate.

For example:

  1. Real-time monitoring allows you to detect spikes in energy usage immediately.
  2. Centralized data helps you manage multiple devices from a single platform.
  3. Visualization tools simplify complex data, making it easier to spot inefficiencies.

Promoting Sustainability

These tools support sustainable energy practices by providing actionable insights. You can use the data to reduce your carbon footprint and align your operations with global sustainability goals. Monitoring energy usage also helps you optimize cooling systems, which often consume a large portion of power in data centers.

Note: Sustainable practices not only benefit the environment but also enhance your facility’s reputation as a responsible organization.

Real-Life Application

Imagine a scenario where your data center experiences a sudden spike in energy consumption. Without smart meters, identifying the source of the problem could take hours or even days. With these tools, you can pinpoint the issue in real-time and take immediate action. This proactive approach minimizes downtime and prevents costly repairs.

Smart meters and energy monitoring systems are essential for modern data centers. They provide the insights you need to optimize energy usage, reduce costs, and promote sustainability. By adopting these technologies, you ensure your facility operates efficiently and responsibly.

Best Practices for Monitoring Data Center Power Usage

Set Alerts for Power Thresholds

Setting alerts for power thresholds is a proactive way to manage power usage in your data center. Alerts notify you when energy consumption exceeds predefined limits, allowing you to address issues before they escalate. For example, intelligent PDUs like NBYOSUN’s 42U IEC 36 C13 6 C19 3Phase Monitored IP PDU can send real-time alerts when circuits approach their capacity. This helps you prevent overloads and maintain operational stability.

Statistical validation methods ensure that alerts trigger only when necessary. These methods account for data variability, reducing false alarms caused by random fluctuations. For instance, an alert might activate only when energy consumption surpasses a threshold by a significant margin, ensuring reliability. By setting these thresholds, you can minimize downtime and unnecessary power use, leading to long-term cost savings.

Tip: Configure alerts for critical metrics like temperature, humidity, and circuit load to enhance energy efficiency and protect your equipment.

Regularly Analyze Power Usage Trends

Analyzing power usage trends helps you identify inefficiencies and plan for future energy needs. Historical data analysis systems track energy consumption over time, providing insights for long-term capacity management. Predictive analytics solutions go a step further by forecasting energy requirements using AI and regression algorithms. These methods can reduce Power Usage Effectiveness (PUE) to as low as 1.2, significantly improving energy efficiency.

Analysis MethodDescription
Real-time monitoring solutionsProvide immediate feedback on power consumption and alert operators to anomalies.
Historical data analysis systemsTrack energy usage trends over time for long-term planning and capacity management.
Predictive analytics solutionsUtilize AI and regression algorithms to forecast power requirements and potential system failures.
Automated control systemsAutomatically respond to power-related thresholds to prevent overloads and maintain system stability.

By leveraging these methods, you can implement energy saving measures that align with your operational goals. Regular analysis also helps you adapt to changing demands, ensuring your data center operates efficiently.

Optimize Power Distribution Across Racks

Optimizing power distribution across racks ensures balanced energy usage and prevents equipment overload. Robust operation strategies, such as dynamic voltage and frequency scaling (DVFS), minimize power consumption by adjusting energy supply based on demand. Distributionally robust optimization addresses workload uncertainty, ensuring efficient power allocation even under variable conditions.

StrategyDescription
Robust OperationMinimizes power consumption in data centers through flexible substation integration and dynamic voltage and frequency scaling (DVFS).
Distributionally Robust OptimizationAddresses workload uncertainty to optimize power consumption in data centers.

Machine learning algorithms enhance these strategies by forecasting electricity usage based on variables like server load and equipment density. Real-time adjustments improve accuracy, ensuring optimal energy distribution. Tools like NBYOSUN’s smart PDUs provide detailed rack-level data, enabling you to manage power usage effectively.

Note: Balanced power distribution reduces cooling demands, further enhancing energy efficiency and lowering operational costs.

Conduct Periodic Energy Audits

Conducting regular energy audits ensures your data center operates efficiently. These audits help you identify inefficiencies, reduce energy waste, and improve overall performance. By analyzing power usage patterns, you can uncover areas where energy-saving measures can make the most impact.

Start by reviewing your facility’s Power Usage Effectiveness (PUE) and other key metrics. Compare these values to industry benchmarks to assess your performance. For example, if your PUE is higher than 1.5, you may need to optimize cooling systems or upgrade outdated equipment. Regular audits also help you track the effectiveness of past energy-saving initiatives.

Tip: Use tools like NBYOSUN’s smart PDUs to collect accurate data during audits. These devices provide real-time insights into power consumption, helping you pinpoint inefficiencies.

Energy audits also reveal underutilized equipment. Ghost servers, which consume power without contributing to operations, are a common issue in data centers. Identifying and decommissioning these servers can significantly reduce energy costs. Additionally, audits help you plan for future energy needs by analyzing usage trends and forecasting demand.

By conducting periodic energy audits, you ensure your data center remains efficient and sustainable. This proactive approach not only lowers operational costs but also supports your sustainability goals.

Integrate Monitoring Tools with Automation Systems

Integrating monitoring tools with automation systems enhances energy management in your data center. Automation systems streamline operations by responding to real-time data from monitoring tools. This integration improves efficiency and reduces energy waste.

For instance, Lakeland Community College implemented ABB Ability™ Data Center Automation. This system reduced electricity use by 40%, natural gas use by 49%, and water/sewer usage by 30%. It also improved operational visibility, enabling better energy management. Similarly, Ericsson used the same system to cut energy usage by 40% while optimizing spending.

Note: Automation systems like ABB Ability™ integrate subsystems for comprehensive monitoring and control. This ensures your data center operates efficiently and sustainably.

Automation systems also help you maintain optimal environmental conditions. By integrating with tools like NBYOSUN’s smart PDUs, these systems can adjust cooling settings based on real-time temperature and humidity data. This reduces overcooling and prevents energy waste.

Integrating monitoring tools with automation systems allows you to automate repetitive tasks, such as adjusting power distribution or activating cooling systems. This reduces manual intervention, saving time and minimizing errors. With this approach, you can achieve a more efficient, reliable, and sustainable data center.


Monitoring power usage in data centers is essential for operational efficiency and cost savings. Advanced systems help you identify energy wastage, streamline processes, and reduce peak demand charges. They also support energy efficiency initiatives by providing actionable data for tailored strategies.

Adopting tools like NBYOSUN’s Smart PDUs enhances your ability to manage power effectively. These devices reduce downtime by 30% and save up to $50,000 annually through improved efficiency. Their real-time monitoring capabilities ensure proactive energy management, aligning your operations with sustainability goals.

Long-term benefits include lower operational costs, reduced environmental impact, and optimized energy use. By implementing best practices such as energy audits, virtualization, and renewable energy adoption, you create a sustainable and future-ready data center.

FAQ

What is the role of a smart PDU in monitoring power usage?

A smart PDU tracks energy consumption in real time. It provides data on power usage, environmental conditions, and circuit loads. This helps you optimize energy distribution, prevent overloads, and reduce operational costs. Devices like NBYOSUN’s smart PDUs also offer remote management for added convenience.

Tip: Use smart PDUs to monitor and control power remotely for better efficiency.


How does monitoring PUE improve energy efficiency?

Monitoring Power Usage Effectiveness (PUE) helps you identify energy inefficiencies. A lower PUE value means your data center uses energy more effectively. By tracking PUE, you can pinpoint areas for improvement, such as cooling systems or lighting, and implement strategies to reduce waste.


Why is balancing rack power density important?

Balancing rack power density prevents equipment overload and overheating. Uneven energy distribution can strain certain racks while leaving others underutilized. Monitoring tools, like NBYOSUN’s smart PDUs, provide real-time data to help you distribute power evenly, improving cooling efficiency and operational reliability.


Can environmental sensors reduce energy costs?

Yes, environmental sensors monitor temperature and humidity, helping you maintain optimal conditions. Overcooling wastes energy, while overheating damages equipment. Sensors provide real-time data, allowing you to adjust cooling systems efficiently. This reduces energy costs and extends the lifespan of your equipment.

Note: A 1°C reduction in overcooling can save up to 8.5% in cooling energy costs.


How do energy audits benefit data centers?

Energy audits identify inefficiencies and help you optimize power usage. They reveal underutilized equipment, like ghost servers, and highlight areas for improvement. Regular audits ensure your data center operates efficiently, reducing costs and supporting sustainability goals.

Example: Decommissioning ghost servers can significantly lower energy expenses.

See Also

Understanding The Importance Of An Auto Transfer Switch

Key Advantages Of Using An Auto Transfer Switch PDU

PDU Related Blogs