Banking-Grade Intelligent PDU Solutions Malaysia
Southeast Asia’s high-humidity climate causes frequent data center power failures. A Malaysian bank faced near-disaster when PDU connector corrosion triggered monitoring blackout in march.
Therefore, Yosun targets this kind of situation,release humidity-resistant smart PDU Solution.This splution solves:
Loose connections & signal loss
Delayed temperature response
Near-miss 2-hour outage during emergency troubleshooting
Legacy PDU’s ≈3% accuracy failed:
Financial audit requirements (ANSI/IEC Class 1 ≤1%)
Micro-current fluctuation detection (<0.1A)
Limited daisy-chaining capacity
Obsolete protocols (SNMP V1)
Data silos preventing SIEM platform integration
3D rack temperature/humidity
Water leak/smoke/CO₂ levels
Physical security (door sensors)
At Yosun, we deliver intelligent PDU solutions tailored for financial-grade data centers. Our six core capabilities are purpose-built for banking IT environments, where secure power distribution, energy efficiency, and compliance are non-negotiable.
The advanced C39 anti-corrosion locking mechanism ensures stable connections in high-humidity conditions. Our Class 1 precision power monitoring captures real-time voltage, current, kWh, and PF data with 0.1% accuracy, meeting audit requirements.
We support modern IPv6 networks, MQTT protocols, and full SNMP/Modbus TCP integration, enabling scalable and future-proof deployments. With AI-powered DCIM automation, including real-time thermal mapping and RBAC, operations become smarter and faster.
Each outlet is trackable for per-device energy usage, supporting carbon reporting and ESG compliance. Compared to traditional PDUs, Yosun’s solution reduces self-consumption by 30% and emergency repair rates by 70%, cutting total cost of ownership.
For financial institutions, this is more than a power system—it’s infrastructure reliability built for the future.
200N anti-vibration force (2× industry standard)
-55°C to 75°C operating range (60°C version deployed in Malaysia)
Full IEC320 compatibility: C14/C16/C18/C20/C22/C24
Load-balanced L1/L2/L3 outlet layout
Bank-Level Power Monitoring
Voltage/current/kW/kWh/PF monitoring
0.1% display + 1% measurement accuracy (IEC 62053-21 Class 1 certified)
0.001A milliamp sensitivity
*0.1% ultra-precision optional*
Rack Micro-Environment Surveillance
6× temperature/humidity sensors
3× door sensors + 1× smoke + 1× water leak + 1× CO₂
Expandable for airflow/IR control/SF6 gas
IPv6 + MQTT 协议 (千兆以太网)
适用于大型服务器机房的99 个单元菊花链
用于审计跟踪的1ms 时钟同步
多协议支持:Modbus TCP/SNMP v1-v3
Local LED display (time/power parameters)
Automated policies (e.g., off-peak shutdown)
Pre-configured 98 sensor templates (70% faster deployment)
RBAC access control
Real-time thermal mapping & load analytics
End-to-end encryption (GDPR compliant)
Outlet-level alert pinpointing (rack/PDU/circuit/outlet)
Integrated physical-logical views
Smoke/door sensor redundancy
Per-device kWh tracking for carbon reporting
30% lower self-power consumption
Cost-efficient APC/Vertiv/Eaton alternative
70% fewer emergency repairs
The bank’s results speak for themselves. Unstable connections caused by oxidation were a constant headache—now solved by our 99% locking reliability with the C39 module. What was once non‑compliant “≈3% power accuracy” is now real‑time power monitoring at Class 1 precision, fully audit‑ready. Emergency response dropped from hours to minutes‑level incident response, and proactive overheat & humidity alerts replaced zero warnings before. By switching from expensive international PDUs to our cost‑effective PDU alternative, the bank slashed total cost of ownership without sacrificing quality. These measurable gains in data center power management, compliance, and operational efficiency prove Yosun’s solution is built for the demands of modern financial data centers.
Performance Metric | Before Upgrade | After Upgrade |
---|---|---|
Connection Reliability | Frequent loosening due to oxidation | 99% lock rate (C39 module) |
Monitoring Accuracy | ≈3% (non-compliant) | 1% (IEC 62053-21 Class 1) |
Response Time | 2 hours (emergency case) | Minute-level |
Risk Prevention | 0 successful alerts | Multiple overheat/humidity alerts |
Procurement Cost | High (international brands) | Optimized (alternative to Vertiv/APC) |
6 great reasons to join us
A Professional And Leading Manufacturer
For OEM
& ODM Power Distribution Unit (PDU)
You Can Trust
CONTACT
Ningbo YOSUN Electric Technology Co., LTD
Leading Professional Manufacturer in PDU Power Solutions
Contact Info.