How Do Power Distribution Units Work in Data Centers

Table of Contents
How Do Power Distribution Units Work in Data Centers

A power distribution unit works by delivering stable electricity to multiple devices in a data center, ensuring each piece of equipment receives the power it needs for safe, continuous operation. Understanding how does a power distribution unit work is essential because reliable power distribution is critical for data center infrastructure—downtime can disrupt services and damage equipment. The table below shows that 11% of data center downtime comes from power distribution unit failures.

Cause of Data Center DowntimePercentage
Power Distribution Unit (PDU) Failure11%

PDUs help maintain uptime by providing stable power, reducing cable clutter, and supporting remote management. NBYOSUN offers certified, high-quality PDUs trusted by top companies, highlighting the advantages of using a power distribution unit for essential operations.

How Does a Power Distribution Unit Work

Power Distribution Basics

A power distribution unit plays a vital role in every data center. It acts as the bridge between the main power source and the sensitive IT equipment. When asking how does a power distribution unit work, it helps to look at the journey of electricity. Power enters the data center from sources like utility lines, generators, or uninterruptible power supplies (UPS). The PDU receives this power and then distributes it to each rack or cabinet.

PDUs do not generate electricity. Instead, they manage and distribute it to all connected devices. This process ensures that servers, switches, and cooling fans receive the correct voltage and current. Many data centers use three-phase power, which provides a steady and efficient flow of electricity. Transformers inside the PDU step down high voltages to safer levels for IT equipment. This conversion protects devices from surges and keeps operations stable.

Modern PDUs offer more than just basic distribution. They include features like real-time load monitoring, digital meters, and network interfaces. These tools allow data center managers to track power usage, balance electrical loads, and prevent overloads. Advanced PDUs can even be upgraded or serviced without shutting down connected equipment, which helps minimize downtime.

Tip: Always check how much power your equipment needs before choosing a PDU. This ensures safe and efficient operation.

The main components of a power distribution unit include:

PDUs support high-density power needs and adapt to changing demands in modern data centers. They also integrate with other power infrastructure, such as UPS systems and generators, to ensure continuous and reliable power delivery.

Input and Output Connections

Understanding how does a power distribution unit work also involves looking at its input and output connections. The input connection is where the PDU receives electricity from the main supply. This could be a C-Form socket, an industrial plug, or a direct connection to a power panel. The output connections are the sockets or outlets where IT equipment plugs in.

PDUs in data centers often feature a variety of output sockets. These include IEC C13 and C19 outlets, which are common for servers and network devices. Some PDUs also offer regional socket types, such as UK (Type G), US (Type B), or EU (Type E/F) outlets. The number of outlets can range from 8 to 24 or more, depending on the model.

Connection TypeExamples / Details
Input ConnectionsC-Form sockets, industrial plugs, direct panel inputs
Output ConnectionsIEC C13, IEC C19, Neutrik powerCon, regional sockets
Additional FeaturesRack-mount units, power monitoring, overload protection

Standardization of these connections is important. It ensures that equipment from different manufacturers can work together without issues. Standards like ANSI/TIA-568 and ISO/IEC 11801 define hardware specifications and connector types. This reduces errors, prevents downtime, and makes it easier to expand or upgrade the data center.

PDUs also perform power conversions to match the needs of connected devices. They may change alternating current (AC) voltage levels using transformers or convert AC to direct current (DC) for certain equipment. This flexibility allows the PDU to safely distribute power to many types of devices.

When considering how power distribution units work, it is clear that both the input and output connections must match the requirements of the data center. Proper connections help maintain stability, reduce cable clutter, and support future upgrades.

PDU Types and Features

Basic and Smart PDU

Data centers use different types of pdus to meet various needs. The most common are basic and smart pdus. A basic pdu works like a simple power strip. It distributes electricity to multiple devices but does not offer any monitoring or control features. This makes it a good choice for smaller setups or places where remote management is not needed.

Smart pdus, also called intelligent pdus, provide advanced features that help data center managers monitor and control power use. These units collect important power metrics such as voltage, current, energy, and power factor. They allow remote monitoring through network connections like web interfaces or SNMP. Smart pdus can also control individual outlets, letting operators turn devices on or off from a distance. This helps with troubleshooting and saves energy by powering down unused equipment.

Smart pdus support integration with data center infrastructure management (DCIM) systems. This allows for centralized control and better planning for future growth.

Here is a comparison of key features:

Feature / PDU TypeBasic PDUMetered Smart PDUMonitored Smart PDUSwitched Smart PDU
Power DistributionYesYesYesYes
Data CollectionNoLocal onlyRemote, real-timeRemote, real-time
Network ConnectivityNoNoYesYes
Historical DataNoNoYesYes
Alarm NotificationsNoNoYesYes
Remote ControlNoNoNoYes (outlet-level)
Upgrade OptionN/AVia Smart Power CableN/AN/A

Smart pdus help data centers save energy and reduce costs. They provide real-time alerts for power problems and allow remote management, which means fewer on-site visits. These features make smart pdus a valuable tool for keeping data centers running smoothly.

NBYOSUN 3 Phase 32A IEC C13 C19 0U PDU

NBYOSUN offers a wide range of power distribution units designed for reliability and safety. The 3 Phase 32A IEC C13 C19 0U pdu stands out as a robust solution for high-demand environments like data centers and server rooms. This model features a heavy-duty aluminum alloy housing, which gives it strong impact resistance and long-lasting durability.

The unit provides 24 outlets, including 14 locking IEC60320 C13 and 10 locking IEC60320 C19 sockets. These locking outlets prevent accidental disconnections, which is important for critical equipment. The pdu supports up to 32A and 250V, delivering a maximum of 24KW. It comes with a 3-phase 32A circuit breaker for overload protection, ensuring that connected devices stay safe from electrical faults.

NBYOSUN’s pdus meet strict international standards. Certifications include ISO9001, CE, and RoHS. These certifications show that the products have passed rigorous testing for quality, safety, and environmental compliance. Major clients like China Mobile and Lenovo trust NBYOSUN for their data center needs.

Key features of the NBYOSUN 3 Phase 32A IEC C13 C19 0U pdu include:

  • Heavy-duty aluminum alloy housing for durability
  • 24 outlets (14 locking C13 + 10 locking C19)
  • Overload protection with a 3P 32A circuit breaker
  • Locking outlets to prevent accidental unplugging
  • Flexible installation with detachable and reversible mounting ears
  • Certified to ISO9001, CE, and RoHS standards
Specification/FeatureDetails
ModelYS1524-3P32-C13C19
Housing MaterialHeavy-duty Aluminum alloy
Size1420 x 55 x 45 mm
Outlets14 locking IEC60320 C13 + 10 locking IEC60320 C19 (24 total)
Electrical Rating32A, 250V, 24KW max, 50Hz
Circuit Breaker3P 32A overload protector
CertificationsISO9001, CE, RoHS
Suitable EnvironmentsData centers, server rooms, industrial facilities

This power distribution unit is ideal for supporting multiple pieces of equipment in a single rack. Its strong construction and advanced safety features make it a reliable choice for mission-critical operations.

Overload Protection and Safety

Safety is a top priority in any data center. A pdu must protect sensitive equipment from electrical problems like overloads, surges, and short circuits. Built-in circuit breakers detect sudden increases in load and isolate the affected section. This prevents damage to equipment and reduces the risk of downtime.

Surge protection absorbs voltage spikes, keeping power delivery stable. Real-time monitoring allows operators to spot overloads early and respond quickly. Load balancing spreads power evenly across circuits, which helps prevent failures. Data centers using advanced pdus report up to a 30% reduction in downtime incidents and significant cost savings each year.

Many pdus now include hot-swap features. This means technicians can replace parts without shutting down connected equipment, minimizing service interruptions.

For mission-critical environments, pdus should have side-mounted surge protectors rated between 200,000 and 300,000 AMPs. These protectors are easy to replace and help maintain uptime. Intelligent pdus also support dry relay contacts for monitoring, which avoids noisy alarms and keeps the environment quiet.

NBYOSUN’s power distribution units undergo strict testing for overload protection and circuit breaker performance. The company’s commitment to safety and quality ensures that each pdu can handle the demands of modern data centers.

Choosing the Right PDU

Power Requirements

Selecting the right pdu for a data center starts with understanding how much power your equipment needs. Each device in a rack draws a certain amount of electricity. Data center managers must add up the wattage of all IT equipment, cooling systems, and auxiliary devices. The table below shows a typical breakdown:

FactorDescription/Value
IT Equipment Wattage150,000W
Cooling System Wattage50,000W
PDUs and Other Equipment Wattage20,000W
Total Wattage220,000W
Power RedundancyAdd wattage of backup systems if N+1 redundancy
Power Usage Effectiveness (PUE)Ratio: Total Data Center Wattage / IT Equipment Wattage
Sustainability ConsiderationsUse of renewable energy, efficient cooling, and sustainable materials

To calculate the total power requirement, managers should:

  1. Learn the basics: Amps, volts, and watts.
  2. Use the formula: Watts = Amps × Volts.
  3. Add the power draw of all devices.
  4. Check real-time readouts or equipment specs.
  5. Include infrastructure like UPS and transformers.
  6. Factor in billing methods for power provisioning.

Other factors, such as hardware efficiency, software optimization, and cooling methods, also affect total power needs. Planning for future growth means choosing a pdu that can handle increased loads and new technologies.

Outlet Types and Compatibility

Finding the right type of pdu depends on matching outlet types to the equipment in use. Most servers and storage devices use IEC C13/C14 or C19/C20 connectors. The table below lists common outlet types and their compatibility:

Outlet TypeVoltage RatingCurrent RatingTypical Use CaseNotes on Compatibility
IEC C13/C14Up to 250V10A (Intl), 15A (UL)Servers, storage devicesWidely used, matches many server power supplies
IEC C19/C20Up to 250V16A (Intl), 20A (UL)High power devices, blade serversSupports higher current, suitable for dense racks
NEMA L6-20RUp to 250V20A (16A rated)High power blade serversLocking outlet, less common but used for high power
NEMA L6-30RUp to 250V30A (24A rated)High power blade serversLocking outlet, supports very high current
NEMA L21-30R208V (3-phase)30AThree-phase Wye PDUsUsed in Wye configurations, supports 120V/208V outlets
Bar chart comparing max current ratings of common data center PDU outlet types

Outlet configuration impacts flexibility and scalability. Universal input rack PDUs allow both single-phase and three-phase cords in one chassis. This flexibility helps data centers adapt to changing needs without replacing equipment. Intelligent PDUs with remote monitoring and modular designs also support future expansion.

NBYOSUN Custom Solutions

NBYOSUN helps with finding the right type of pdu by offering custom solutions for different data center needs. The company provides options for input and output voltage, outlet configurations, and current capacities. Customers can choose from up to 48 outlets, including U-Lock C13, U-Lock C19, and P-Lock Combo types. NBYOSUN also integrates built-in diagnostics, LED indicators, and environmental sensors for temperature, humidity, and smoke.

NBYOSUN’s engineers work with clients to design, prototype, and test PDUs that fit unique requirements. This approach ensures seamless integration and reliable performance.

Custom PDUs from NBYOSUN include features like intelligent load balancing, power factor optimization, and remote management. These units support energy efficiency and operational control. All products meet international certifications such as UL, CE, RoHS, and ISO 9001. After-sales support and warranties provide peace of mind and ongoing assistance.

When finding the right type of pdu, certifications and support matter as much as technical features. NBYOSUN’s commitment to quality and customer service makes it a trusted partner for data center power solutions.

PDU Installation in Data Centers

Rack-Mount and Vertical Options

Data centers use two main installation methods for power distribution units: rack-mount (horizontal) and vertical (Zero-U) options. Each method offers unique benefits and challenges. The table below compares key features:

Feature/AspectVertical PDUs (Zero-U)Horizontal PDUs (Rack-mount)
Rack Space UtilizationSaves horizontal rack space; Zero-U design frees up 1U or 2U for equipmentOccupies 1U or 2U of rack space, reducing space for other equipment
Outlet DensityHigh, up to 60 outlets; powers many devicesLower, typically 6–16 outlets; for moderate needs
AccessibilityHarder to access in tight racks; needs careful planningEasy front access for quick connections
Cable ManagementImproves airflow along rack edges; needs planningCleaner layout but uses rack units
Power HandlingHandles higher loads; ideal for large data centersBest for smaller setups
Use CasesLarge, high-density data centersSmall setups, offices, easy maintenance
DrawbacksNeeds vertical clearance; can be hard to accessUses valuable rack space; lower outlet density

Vertical PDUs mount along the rack’s edge, saving space for servers and switches. This design supports high outlet density and better airflow, but it requires careful cable management. Poor cable planning can block airflow, causing equipment to overheat. Horizontal PDUs fit into rack units and offer easy access to outlets. They suit smaller setups but reduce available rack space for IT equipment.

Good cable management keeps airflow paths clear and prevents overheating. Using Zero-U cable managers and planning cable routes helps maintain cooling efficiency and reduces energy costs.

Integration with UPS and Generators

Reliable power in data centers depends on seamless integration between PDUs, uninterruptible power supplies (UPS), and backup generators. The process follows these steps:

  1. Utility power enters the facility and steps down to usable voltage through transformers.
  2. UPS systems condition the power and provide instant backup during outages.
  3. Conditioned power flows from the UPS to the PDUs, which distribute it to racks and devices.
  4. If both grid and UPS power fail, backup generators start automatically to supply emergency power.
  5. Redundant designs, such as N+1 or 2N, ensure that a backup is always available for critical systems.

UPS units protect sensitive equipment from voltage spikes and sags. They bridge the gap until generators start, preventing data loss and downtime. Redundant power paths and regular maintenance checks—like battery health and load balancing—help keep systems running smoothly. This setup supports business continuity and keeps data centers operational during power disturbances.

Regular testing and monitoring of UPS, PDUs, and generators ensure that backup systems work when needed, increasing reliability and reducing the risk of outages.


Power distribution units keep data centers running safely and efficiently. Certified PDUs, like those from NBYOSUN, offer strong build quality, advanced monitoring, and support for future growth. Key considerations include:

Data center managers should review their requirements and consult NBYOSUN for tailored, high-quality PDU solutions that support long-term performance.

FAQ

What is the main purpose of a PDU in a data center?

A PDU distributes electrical power to multiple devices in a data center. It ensures each server, switch, or storage unit receives safe and reliable electricity. This helps prevent downtime and protects equipment from electrical problems.

How does overload protection work in a PDU?

Overload protection uses a circuit breaker. When the current exceeds a safe limit, the breaker trips and stops the flow of electricity. This action protects connected devices from damage caused by electrical surges or faults.

Why do data centers use locking outlets on PDUs?

Locking outlets prevent accidental unplugging of critical equipment. This feature keeps power connections secure, which is important for maintaining uptime in busy data centers. NBYOSUN’s PDUs include locking IEC C13 and C19 outlets for extra safety.

What certifications should a reliable PDU have?

Reliable PDUs should have certifications like ISO9001, CE, UL, and RoHS. These certifications show the product meets international safety and quality standards. NBYOSUN’s PDUs carry these certifications, ensuring dependable performance in demanding environments.

Can a PDU be customized for specific data center needs?

Yes. Many providers, including NBYOSUN, offer custom PDUs. Customers can choose outlet types, voltage, current ratings, and monitoring features. Custom solutions help match the PDU to the exact requirements of each data center.

See Also

Key Reasons Why Auto Transfer Switch PDUs Are Vital

Unmissable Advantages Of Using Auto Transfer Switch PDUs

PDU Related Blogs