Everything You Need to Know About 19 Inch Rack PDUs for Server Cabinets

Table of Contents
Everything You Need to Know About 19 Inch Rack PDUs for Server Cabinets

Selecting the right 19 inch rack pdu for your server cabinet plays a key role in ensuring continual reliable power supply. When you choose a well-designed 19 inch rack pdu, you help protect your IT equipment from electrical faults and overloads. Good PDUs also improve airflow and cooling, which can reduce overheating and extend the life of your devices. Organized cable management and secure installation add to the reliability of your setup. NBYOSUN offers certified and high-quality solutions that support safe and efficient operations in many environments.

What Is a 19 Inch Rack PDU?

Definition and Function

A 19 inch rack pdu is a power distribution unit designed to fit perfectly into the standard 19-inch server rack. You can mount this device either vertically along the back of the rack or horizontally in a 1U or 2U space. Vertical PDUs, sometimes called 0U PDUs, save valuable rack space and often provide more outlets. Horizontal PDUs fit like other equipment in the rack and measure exactly 19 inches wide. These units distribute power efficiently to all your devices inside the rack. They come in different plug and outlet types, so you can match your server’s voltage and power needs.

The main job of a power distribution unit is to deliver electricity from a single source to multiple devices in your server rack. You get several important functions from a server rack pdu:

  • Power distribution: The unit sends power to each device through its outlets.
  • Power management: Some PDUs let you monitor current, voltage, and energy use in real time.
  • Remote control: Advanced PDUs allow you to turn outlets on or off from a distance.
  • Fault alarm: The unit can alert you if it detects a problem with the power.
  • Safety protection: Built-in features protect your equipment from overloads, short circuits, or voltage spikes.

Tip: Choosing the right power distribution units for server racks helps you manage energy and keep your equipment safe.

Importance in Server Cabinets

You need a 19 inch rack pdu in every modern server rack. These units make sure each server and device gets reliable power. Rack-mount PDUs distribute electricity to many devices at once, which is essential as you add more servers to your rack. Vertical PDUs do not take up extra rack space, so you have more room for your equipment and better cable management. They also help with cooling by not blocking airflow.

Advanced server rack pdu models offer remote monitoring and control. This means you can check power status and fix problems without being in the server room. PDUs help prevent overloads and keep your critical IT equipment running all the time. They also support higher power density as your server needs grow. The 19-inch rack standard ensures that your power distribution unit will fit with any rack-mount equipment, making it a key part of your server infrastructure.

Power Distribution Unit Types

When you set up a server rack, you need to know the different types of PDUs available. Each type of power distribution unit offers unique features for your server cabinet. Understanding these options helps you choose the best PDU for your needs.

Basic PDUs

A basic PDU gives you simple and reliable power distribution. You use it to send electricity from one source to many devices in your server rack. Basic PDUs do not have monitoring or remote control. They often include a master on/off switch and fit well in small server rooms, offices, or banks. You can find them in both horizontal and vertical mounting styles. Many basic PDUs come in 1RU or 2RU sizes and offer socket counts from 8 to 24. The table below shows how a basic PDU compares to an intelligent PDU:

PDU TypeFeaturesTypical Use Cases
Basic PDUSimple power distribution, no monitoring or remote management, includes master on/off switch, compact sizeSmall server rooms, offices, hospitals, banks; environments prioritizing simplicity, cost-effectiveness, and low-density setups
Intelligent PDUAdvanced features like real-time monitoring, outlet-level metering, remote control, environmental sensors, integration with management toolsData centers, managed rack setups requiring precise power management, scalability, and operational reliability

Note: Basic PDUs work best when you want a cost-effective solution for a low-density server rack.

Metered PDUs

A metered PDU lets you see how much power your server rack uses. You get a built-in display that shows the current in amps. Some models have two meters to monitor different load banks. You can watch the LED display to check power use and prevent overloads. Metered PDUs help you balance the load across your devices. Some advanced models allow remote monitoring through network protocols. This feature helps you keep your server safe and avoid downtime.

Switched and Smart PDUs

Switched PDUs give you remote control over each outlet. You can turn devices on or off from anywhere. This feature helps you reboot equipment quickly and manage power cycles. Smart PDUs go further. They let you monitor power use in real time at both the unit and outlet levels. You can track temperature and humidity with built-in sensors. Smart PDUs send alerts if something goes wrong, like an overload. You can also schedule power cycles to save energy. These PDUs work well in high-density server racks and data centers. They support integration with management software, making it easy to control many racks at once.

NBYOSUN Product Range

NBYOSUN offers a wide range of power distribution units for 19 inch racks. You can choose from basic PDUs, metered PDUs, smart PDUs, and heavy-duty models. For example, the 8 way type F (Shuko) 19 inch server rack PDU fits many server cabinets. NBYOSUN also provides options with different plug types, socket counts, and amperage ratings. You can customize your rack mount PDU with features like overload protection or intelligent monitoring. These products use strong materials like aluminum and plastic for durability. NBYOSUN supports both horizontal and vertical mounting, so you can match your server rack setup. Their power distribution units meet international standards and work in data centers, server rooms, and open racks.

How to Choose a PDU

Selecting the right rack PDU is a key step in ensuring continual reliable power supply for your server cabinet. You want to make sure your equipment stays safe, organized, and ready for future growth. This pdu buying guide will help you understand the most important factors.

Assessing Power Needs

You should start by checking how much power your devices use. This step helps you avoid overloads and keeps your system running smoothly. Follow these steps to assess your power needs:

  1. Add up the power consumption of all devices in your rack. Check the nameplate ratings or use real-time monitoring tools for accuracy.
  2. Decide if you need single-phase or three-phase power. Three-phase works better for larger loads and higher efficiency.
  3. Pick a PDU with a capacity higher than your total power needs. This gives you room for future expansion.
  4. Match the outlet types to your equipment. For example, use IEC C13 for low-power devices and C19 for high-power servers.
  5. Choose the right mounting option. Horizontal mounting fits smaller cabinets, while vertical mounting works best for high-density racks.
  6. Think about advanced features like metering, monitoring, or remote management. These features improve reliability and make your job easier.
  7. Make sure the plug type matches your equipment and power source.
  8. Plan for scalability. Select a PDU that can handle more devices as your needs grow.
  9. If your servers have redundant power supplies, look for PDUs that support outlet grouping or linked outputs.
  10. Consider alarm monitoring. This feature helps you get alerts quickly if there is a power issue.

Tip: Always choose a PDU with extra capacity to support new devices in the future.

Mounting Options: Horizontal vs Vertical

You need to decide how to install your PDU in the rack. Both horizontal and vertical mounting have benefits.

  • Vertical mounting: You can mount the PDU at the back of the rack. This saves space and improves airflow. Vertical PDUs work well in high-density racks and let you add more outlets without blocking equipment.
  • Horizontal mounting: This fits the standard 19-inch width of your cabinet. Horizontal PDUs are easy to install in 1U or 2U spaces and work well in smaller racks.

Good cable management is important for both options. Use cable managers to keep cables neat and prevent airflow blockages. Label cables and use shorter cords to reduce clutter. Separate power and data cables to avoid interference. Install blanking panels and use perforated doors to improve cooling. Arrange hot and cold aisles to keep air moving efficiently.

Note: Vertical mounting is best for saving space and supporting more devices, while horizontal mounting is simple and fits standard rack spaces.

Outlets and Compatibility

You must check that the PDU outlets match your equipment. The most common outlet types for server and networking gear are IEC320 C13/C14 and C19/C20. C13 and C19 are sockets, while C14 and C20 are plugs. C13 supports up to 10A, and C19 supports up to 16A.

Some devices, like AC/DC adapters, may need BS1363 UK sockets. Locking outlets help prevent accidental unplugging, which improves reliability. Outlet orientation, such as 45° or 90°, makes cable management easier, especially if you use two PDUs in one rack. Choose the right power cord length and label each cord for safety and organization.

Callout: Always match the outlet type and orientation to your devices for safe and efficient operation.

Safety and Certifications

Safety is a top priority when you choose a PDU. Certified PDUs use flame-retardant materials and overload protection to prevent electrical faults and fire hazards. You should look for these certifications:

CertificationRegion/MarketPurpose/Focus
CEEuropeHealth, safety, and environmental compliance
ULNorth AmericaElectrical safety and fire resistance
CSACanadaElectrical safety and environmental performance
RoHSGlobalRestriction of hazardous substances
ISO 9001GlobalQuality management system
CCCChinaProduct safety and quality compliance
CBInternationalMutual recognition of safety standards
VDE, GS, NFEuropeElectrical safety, quality, and fire resistance

NBYOSUN PDUs meet many of these international standards, including CE, UL, RoHS, ISO 9001, and CCC. These certifications show a strong commitment to quality and safety. You can also request custom features or outlet types to fit your specific needs.

Practical Checklist for PDU Selection

Use this checklist to help you choose the best PDU for your server cabinet:

  1. Check rack dimensions and weight limits.
  2. Calculate total power needs with extra capacity for growth.
  3. Choose outlet types that match your devices.
  4. Select plug types that fit your power source.
  5. Decide on horizontal or vertical mounting.
  6. Make sure mounting brackets are adjustable.
  7. Plan cable management for airflow and organization.
  8. Look for surge protection and real-time monitoring.
  9. Confirm the PDU supports your rack’s size and ventilation.
  10. Ensure proper airflow to prevent overheating.

Planning for Future Growth and Redundancy

You should always plan for future needs when you select a PDU. Choose a model with extra outlets and higher capacity. Modular designs make it easy to add more power as your setup grows. Use dual power feeds for redundancy, which keeps your equipment running even if one power source fails. Intelligent PDUs with real-time monitoring and remote control help you manage power more efficiently.

Redundancy levels like N+1 or 2N provide backup in case of failure. Metered and monitored PDUs let you track power use and get alerts early. Switched PDUs allow you to control outlets remotely. Color-coded outlets and circuit breakers make maintenance easier. Universal PDUs work in different countries, and branch circuit protection improves safety.

Tip: NBYOSUN offers a wide range of certified PDUs with customization options, so you can build a solution that fits your current and future needs.

Rack Power Distribution Unit Features

Overload Protection

You need strong overload protection in every rack power distribution unit. This is one of the most important PDU features. Most units include automatic power shutoff. This system activates if there is too much current or if the unit gets too hot. Circuit breakers trip when the current goes above safe levels. This stops damage to your equipment. Built-in overload protection also guards against short circuits and power surges. These PDU features help keep your devices safe, reduce downtime, and meet global safety standards.

Tip: Always check for a circuit breaker and automatic shutoff when you choose a rack power distribution unit.

Remote Management and Monitoring

Remote management is a key part of modern PDU features. You can control and monitor your rack power distribution unit from anywhere. This saves time and reduces mistakes. You do not need to visit the server room for every task. Central dashboards show you real-time data about power, temperature, and device status. You can turn outlets on or off remotely. This helps you fix problems quickly and keep your systems running. Advanced PDU features include predictive analytics and health maps. These tools warn you about hot spots or power limits before they cause trouble. You can also use visual tools to find and manage assets. Automated alerts and reports help you make smart decisions and use resources well. These PDU features improve uptime, security, and energy utilization efficiency.

Environmental Monitoring

Environmental monitoring is another important PDU feature. Smart rack power distribution units have sensors for temperature, humidity, and airflow. These sensors give you real-time alerts if something changes. You can see all this data on your management system. This helps you keep your equipment cool and safe. Good environmental monitoring protects your devices from overheating and other risks. It also helps you plan for future needs and save on cooling costs. Many advanced PDU features work with data center management tools. This lets you automate tasks and keep your data center running smoothly.

NBYOSUN 19 Inch 8way French Socket Switch Overload Rack PDU

The NBYOSUN 19 Inch 8way French Socket Switch Overload Rack PDU stands out with its strong PDU features. You get eight French Type E sockets in a 19-inch rack-mount design. The aluminum alloy case resists impacts, fire, rust, and wear. A 2-meter heavy-duty cable and mounting holes make installation easy on walls or workbenches. This rack power distribution unit supports up to 16A and 250V, handling up to 3680W. Safety features include a manual reset switch, indicator light, and a 16A circuit breaker. Overload protection cuts power if there is a short circuit, too much current, or overheating. The internal copper bar welding ensures stable current flow. Extra insulation keeps you safe from electrical contact. You can choose extra options like different circuit breakers, USB chargers, surge protectors, and smart meters. The PDU is CE and NF certified and comes with a 12-month warranty. You can use it in workshops, garages, offices, or living rooms. Custom options for cable length, plug type, and color are also available.

Installation Best Practices

Preparing the Server Cabinet

Before you install a 19 inch rack PDU, you need to get your server cabinet ready. Start by checking your power requirements. Look at the amperage, voltage, and whether you need single-phase or three-phase power. Measure the cabinet’s height, width, and depth to make sure the PDU fits. Decide if you want to mount it vertically or horizontally. Gather tools like screwdrivers, mounting brackets, screws, cable ties, and a measuring tape. Plan your cable management by organizing and labeling cables. This keeps airflow strong and makes future work easier. Check that the PDU matches your power source, including plug type and cord length. Pick a mounting spot that gives you easy access and avoids bending power cords. Always turn off the power and use safety gear like insulated gloves and goggles before you start.

Tip: Good planning helps prevent mistakes and keeps your server running smoothly.

Safe Installation Steps

Follow these steps to install your PDU safely:

  1. Choose a PDU that matches your power needs and has enough outlets for all your server equipment.
  2. If possible, select a PDU with remote monitoring to help manage power use.
  3. Make sure the PDU fits your 19 inch rack and comes with the right mounting hardware.
  4. Install mounting rails or shelves according to the instructions. Check that everything is level and secure.
  5. Use the correct screws and brackets for your rack’s holes.
  6. Manage cables with cable bars to keep them neat and allow for good airflow.
  7. Label every cable for easy troubleshooting.
  8. Leave space for airflow and easy access to all ports.

For extra reliability, use redundancy. Connect your servers to both A and B power feeds. This way, if one feed fails, your servers keep running. Distribute your servers across both feeds and monitor power use to avoid overloads.

Maintenance Tips

Regular maintenance keeps your PDU and server equipment reliable. Inspect your setup often for loose cables, dust, or damage. Clean the PDU and cabinet with anti-static tools to protect sensitive parts and improve cooling. Keep cables organized and labeled to prevent tangling and make repairs easier. Balance the power load across your server to avoid overloads. Make sure nothing blocks airflow around the PDU. Use sensors to watch temperature and get alerts if things get too hot. Update PDU firmware to get new features and security fixes. Always use certified replacement parts. Schedule yearly checks by a certified technician to catch hidden problems and improve energy use.

Note: NBYOSUN offers strong after-sales support, a clear warranty, and certified products. If you find any issues or need help, their support team is ready to assist you at every step.

NBYOSUN Solutions for Data Centers

Smart PDU Solution Overview

You need smart solutions to manage power in your data center. NBYOSUN offers advanced smart PDUs designed for high-density environments. These PDUs help you track and control power at every outlet. You can monitor temperature and humidity to keep your equipment safe. The smart PDUs use strong, flame-resistant materials and have electromagnetic hydraulic circuit breakers for extra safety. You can see real-time data on a rotatable LCD screen right on the device. Remote management lets you control outlets and check power use from anywhere.

Here is a table showing the main features of NBYOSUN’s smart PDUs:

FeatureDescription
Outlet-level monitoringTrack energy use at each outlet for detailed visibility.
Environmental sensorsMonitor temperature and humidity to protect equipment.
Overload protectionCircuit breakers and alerts prevent damage from power surges.
Remote managementControl and monitor outlets from any location.
Multiple protocolsSupports SNMP, HTTP, and more for easy integration.
Customizable optionsTailor the PDU to your data center’s needs.
Safety featuresFlame-resistant materials and advanced circuit breakers.
Rotatable LCD screenView real-time data directly on the device.

Smart PDUs like the 3phase 125A 415V 24 C19 Outlets IP Switched PDU show how you can get strong overload protection, remote management, and easy installation. These features make NBYOSUN a trusted choice for your data center pdu needs.

Benefits for High-Density Environments

High-density data centers need reliable and efficient power management. NBYOSUN’s high-density pdu solutions give you real-time monitoring and remote control at the outlet level. You can spot energy waste and fix it fast. Environmental sensors help you keep the right temperature and humidity, which protects your servers and switches. Intelligent load balancing spreads power evenly, so you avoid overloads and keep your equipment running longer.

You can connect these high-density pdu units with your existing IT systems using common protocols like SNMP and HTTP. This makes it easy to automate and manage power across many racks. Redundancy and failover support mean your high-density setup stays online, even if one power source fails. Alerts and notifications warn you about problems before they cause downtime.

With NBYOSUN’s high-density pdu, you can:

  • Monitor and control power at the rack level for better rack-level power management.
  • Improve cooling by reducing extra heat, which lowers energy costs.
  • Identify underused equipment and move workloads to save power.
  • Support sustainability by using energy more efficiently.

These benefits help you reduce costs, extend equipment life, and keep your high-density data center running smoothly.


Choosing the right 19 inch rack PDU starts with a careful review of your current setup.

  1. Add up your devices’ power needs and check voltage ratings.
  2. Match outlet types and mounting options to your rack.
  3. Look for surge protection and network compatibility.

Certified PDUs from NBYOSUN give you reliable power, advanced monitoring, and strong safety features.

FAQ

What is the main purpose of a 19 inch rack PDU?

You use a 19 inch rack PDU to distribute power safely and efficiently to all devices in your server cabinet. This device helps you organize power connections, prevent overloads, and keep your equipment running smoothly.

How do I know which PDU outlet type I need?

Check the plug type on your equipment. Most servers use IEC C13 or C19 outlets. Match the PDU outlet to your device’s plug. If you use French or Schuko plugs, choose a PDU with those socket types.

Why should I choose a PDU with overload protection?

Overload protection keeps your devices safe. If too much current flows, the PDU shuts off power to prevent damage or fire. You protect your equipment and reduce the risk of downtime.

Can I install a PDU myself?

Yes, you can install a PDU if you follow safety steps. Turn off the power first. Use the right tools and mounting hardware. If you feel unsure, ask a certified technician for help.

What certifications should I look for in a PDU?

Look for certifications like CE, UL, RoHS, and ISO 9001. These show the PDU meets safety and quality standards. NBYOSUN PDUs carry many of these certifications, so you get reliable and safe products.

See Also

Key Reasons Why Auto Transfer Switch PDUs Are Vital

Unmissable Advantages Of Using Auto Transfer Switch PDUs

PDU Related Blogs