YOSUN Smart PDU is a professional-grade network remote monitoring and managing power distribution system, developed according to the world future development trend of the power distribution management technology, combined with the technical requirements of contemporary data center application environment and the latest core technology.

YOSUN Smart PDU provide real-time energy management and on/off control at the outlet level to provide advanced data center energy management.

Features:

  • Hot-swap SPMC(Smart network PDU master controller), flexibly upgrade and maintain the equipment without power interruption

  • Support RS485, SNMP, SSH, TELNET, HTTP and other protocols, adapt to different data communication scenarios *SPMCIP support RS485/SNMP/HTTP

  • Provide remote monitoring and on/off switching control of individual outlets, enable data center managers to have a clear understanding of the running status of equipments.

  • Status keeping feature: After power off / reboot of the device, each outlet will keep the switching status before power off

  • Power sequencing time delays allow users to define the order in which to power up or down attached equipment to avoid circuit overload. 

  • User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. 

  • LCD screen supports rotatable display in four directions, suitable for both horizontal and vertical installation

  • Temperature/humidity, water immersion, smog, etc, monitored by expansion modules, programmable expansion available *SPMCIP support Tempreture/Humidity

  • Support USB/WEB upgrade system, the latest software functions can be obtained (SPMCIP support web upgrade)

  • Support max.9 PDU devices cascade *SPMCIP support max.5 PDU devices cascade

Smart PDU slave controllor(SPSC)

  • Individual outlet level monitoring of PDU can be provided so that data center managers can clearly understand the use of equipment and seek opportunities to improve energy efficiency 

  • Single slave supports a minimum 4-way socket, which can be flexibly configured to support a maximum of 24 ways through slave cascades according to actual needs

  • Status maintenance is supported

  • After power off/restart of the device, each output branch shall maintain the switching state before restart

  • Support abnormal equipment current alarm and overload power off